Multi-tenant EVPN-VXLAN fabrics for hosting and GPU clouds
IP Infusion delivers the multi-tenant data center fabric: OcNOS-DC on qualified switches that give each tenant its own VRF and VNIs on a shared EVPN-VXLAN fabric, and share a service between tenants only by an explicit route leak, under one support contract.
- Best for
- Hosting and GPU cloud operators giving each tenant its own VRF and VNIs on a shared fabric.
- Running at
- Scott DataProsoluceIzarLink
Each tenant sees only its own routes
On a shared fabric, every tenant gets its own VRF on the leaves it uses. The VRF holds only that tenant's routes, until you leak a shared service into it on purpose.
Pick a tenant to see its routing table on Leaf 1
Tenant A. Leaf 1 holds Tenant A's local subnet and the subnet EVPN learns from Leaf 2. Tenant B's routes never appear.
| Prefix | Learned | From |
|---|---|---|
| 10.1.1.0/24 | Local | Leaf 1 |
| 10.1.2.0/24 | EVPN | Leaf 2 |
Tenant B. The same leaves, a different VRF. Tenant B sees only its own subnets.
| Prefix | Learned | From |
|---|---|---|
| 10.2.1.0/24 | Local | Leaf 1 |
| 10.2.3.0/24 | EVPN | Leaf 3 |
Shared services. Import the shared storage subnet into Tenant A by route target. Tenant A can reach it, and Tenant B's routing table does not change.
| Prefix | Learned | From |
|---|---|---|
| 10.1.1.0/24 | Local | Leaf 1 |
| 10.1.2.0/24 | EVPN | Leaf 2 |
| 10.9.0.0/24 | Imported by route target | Shared services, Leaf 3 |
Illustrative. Support varies by switch model.
Operators running multi-tenant fabrics on OcNOS
Scott Data
One of only fourteen multi-tenant organizations in the US with Uptime Institute Tier III certification in both design and facility, running OcNOS on UfiSpace, Edgecore and Celestica hardware.
Read the story →Prosoluce
Its new IP backbone uses EVPN-VXLAN to deliver multi-site and multi-tenant services.
Read the story →IzarLink
Its EVPN-VXLAN core aggregates 25G access into a redundant 100G core and connects its data centers and peering locations.
Read the story →“OcNOS and an open networking strategy hits all the right notes in terms of cost, support, and features. Service providers and OEMs have been using IP Infusion for years.”
Ken Moreano, Co-Founder, President, and CEO of Scott Data
What OcNOS-DC runs for tenants
Isolation, sharing and limits per tenant, from the OcNOS Feature Matrix.
| Capability | What it does | Where |
|---|---|---|
| EVPN-VXLAN | Layer 2 EVPN over VXLAN, with VNIs per tenant | Trident 3 and 4 |
| Inter-VRF route leaking | Shares chosen routes between VRFs | All OcNOS-DC |
| Route leaking over EVPN-VXLAN | Shares a service between tenant VRFs across the fabric | Selected switches |
| Route-target filtering | Filters EVPN routes by route target | Selected switches |
| EVPN multihoming | Single-active or port-active multihoming for a server | Trident 3 and 4 |
| MLAG | Active/active dual-homing for a server across a switch pair | All OcNOS-DC |
| Tenant limits | Per-tenant MAC limits and storm control | Selected switches |
| VXLAN QoS | Classifies and queues tenant traffic on the overlay | Trident 3 and 4 |
| PFC and ECN over VXLAN | Lossless storage traffic on the overlay | Selected switches |
| BGP underlay | EVPN-VXLAN with BGP unnumbered, and EVPN route reflection on the spine | Trident 3 and 4 leaves |
Support varies by switch model and license. Check the OcNOS Feature Matrix.
Switches by role
Tenant leaves run EVPN-VXLAN on Trident switches. The spine routes the underlay traffic.

25G tenant leaf
Edgecore AS7326-56X
Trident 3 · 2.0 Tbps
48 × 25G, 8 × 100G

100G tenant leaf
UfiSpace S9110-32X
Trident 3 · 3.2 Tbps
32 × 100G

400G leaf and border
Edgecore AS9726-32DB
Trident 4 · 12.8 Tbps
32 × 400G

Spine
Edgecore AS9736-64D
Tomahawk 4 · 25.6 Tbps
64 × 400G
See the AI fabric for GPU traffic that needs lossless transport. See the data center fabric for a full data center build. See the full list of qualified switches on the OcNOS Hardware Compatibility List.
Questions about tenant isolation.
Solution brief and datasheet.
The EVPN-VXLAN fabric brief and the OcNOS-DC datasheet to share with your team. Quick form, and the PDF downloads immediately.
Related from the blog
Overlay ECMP in an EVPN-VXLAN Leaf-Spine Fabric, Part 1
How EVPN-VXLAN overlay ECMP load-balances tenant traffic across a Clos leaf-spine fabric
Read the post →Overlay ECMP in an EVPN-VXLAN Leaf-Spine Fabric, Part 2
The second part of the EVPN-VXLAN overlay ECMP walk-through for the shared fabric
Read the post →Plan your multi-tenant fabric.
Tell us your tenants, shared services and switch speeds. An IP Infusion engineer will map them to qualified switches and the isolation design that fits.
EVPN-VXLAN Data Center Fabric
Quick form. Your PDF will download immediately after submit.
✓ Opening your PDF in a new tab.
If it did not open, use the link below.
OcNOS-DC Datasheet
Quick form. Your PDF will download immediately after submit.
✓ Opening your PDF in a new tab.
If it did not open, use the link below.

