OcNOS 6.5 is now generally available for service providers and data center operators. This release advances OcNOS automation capabilities with expanded OpenConfig YANG model support, adds new high-density 400G platforms for aggregation and spine deployments, and delivers Segment Routing improvements including the foundations of Flex-Algo for network slicing.
OpenConfig YANG Model Support
OcNOS 6.5 is a significant step forward for vendor-neutral automation. NETCONF clients can now interact with OcNOS switches using standardized OpenConfig YANG data models — in addition to IP Infusion's native models. This allows operators to use a single automation framework across OcNOS and other OpenConfig-capable devices in their network.
! OcNOS 6.5 -- OpenConfig interface configuration via NETCONF
!
! Enable the NETCONF server (SSH transport, management VRF):
configure terminal
feature netconf-ssh vrf management
commit
exit
!
! Example NETCONF edit-config using the OpenConfig interface model:
! <edit-config>
! <target><running/></target>
! <config>
! <interfaces xmlns="http://openconfig.net/yang/interfaces">
! <interface>
! <name>eth-0-1</name>
! <config>
! <name>eth-0-1</name>
! <description>Uplink to Spine-1</description>
! <enabled>true</enabled>
! </config>
! </interface>
! </interfaces>
! </config>
! </edit-config>
!
! Verify the NETCONF server state. The advertised capability list is returned
! by the NETCONF hello exchange itself, not by a show command.
show netconf server
New Hardware Platforms in OcNOS 6.5
| 플랫폼 | 실리콘 | 포트 | 사용 사례 |
|---|---|---|---|
| UfiSpace S9600-72XC | Broadcom Trident 4 | 48×100G + 8×400G | SP aggregation, 400G migration |
| Edgecore AS9516-32D | Broadcom Tomahawk 3 | 32×400G QSFP-DD | DC spine, 400G fabric |
| UfiSpace S9502-16SMT | Broadcom QUX | 16×SFP+ + 4×100G | Fanless CSR / FWA edge |
Segment Routing Enhancements
OcNOS 6.5 delivers Flex-Algo foundation capabilities for IS-IS SR deployments. Operators can define custom routing algorithms with TE-metric and delay-metric optimization types, laying the groundwork for network slicing deployments that arrive fully in OcNOS 6.6.
EVPN-VXLAN Improvements (Data Center)
OcNOS 6.5 DC expands EVPN-VXLAN operational capabilities including improved MAC/IP route withdrawal timing, enhanced VNI-level statistics, and improved VXLAN tunnel encapsulation performance on supported Broadcom platforms.
- OcNOS 6.5 for Service Providers
- OcNOS 6.5 for Data Centers
- OcNOS 6.6 Release
- OcNOS 기능 매트릭스
- IP Infusion 문의
IP Infusion Product Team
더 깊이 살펴보십시오. 자료를 소장하십시오.